Abstract
To improve the focused ultrasonic beam induced by laser phased array (LPA), the superiority of an improved LPA distribution with conjunction of geometric attenuation and directivity functions of the stimulated ultrasonic beams are investigated theoretically instead of only considering the directivity function. Numerical simulations for the generation of focused longitudinal waves in the thermoelastic regime were implemented to reveal the advantages of the improved LPA design. It is shown that the amplitude of the focused beam increased by 42.1%, and the rise time reduced by 25.0%, as well as spatial sizes narrowed by 50.6% and 41.9% in longitudinal and transverse directions, respectively. In addition, the thermal expansion superposition caused by adjacent laser pulses, which deteriorates the focusing features of the focused beam, should be avoided by setting proper spacing of LPA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.