Abstract

The aim of this work is to present an experimental procedure to improve crack detection in rough surfaces by means of lensless Fourier digital holographic interferometry (DHI). To overcome the problem of analyzing high speckle interferograms that blurs phase maps and hinders, or even prevents, crack detection, it is proposed the application of a non-uniform thermal load to the object under study, as excitation source, instead of the most common uniform heating. Different tests with mock ups of cracks of controlled width allowed us to demonstrate the effect of a non-uniform thermal load, and confirmed the enhancement in DHI information, especially in unwrapping phase maps. Finally, DHI was applied to the detection of a crack in a cast iron sample and the results obtained with both uniform and non-uniform heating procedures were compared and the improvement attained by means of non-uniform heating was confirmed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.