Abstract

SummaryBackgroundAs standard bolus triggering in the pulmonary trunk sometimes fails to achieve sufficient enhancement in the pulmonary arteries, the study investigates an alternative, ‘delayed’ position of the tracking ROI in the descending aorta.Material/MethodsRetrospective analysis of 143 patients suspected of pulmonary embolism investigated with 3 different scanners (16 to 80 rows) in clinical routine. Bolus triggering with 120 hounsfield units (HU) was performed using the pulmonary trunk (n=70) or descending aorta (n=73) after application of 70 to 120 mL of contrast agent, Iomeprol 300. Student’s t-test was applied to compare vascular enhancement. Additional factors were analysed by a regression analysis.ResultsPositioning of the tracking ROI in the descending aorta achieved a significantly higher contrast enhancement in the pulmonary trunk with a mean increase of 63 HU (p<0.001).ConclusionsIn CTA, delayed acquisition by using the descending aorta for bolus triggering can improve the enhancement of the pulmonary trunk to investigate a pulmonary embolism. Furthermore, the scan protocol simultaneously allows to rule out aortic pathologies as an alternative cause for a similar clinical condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.