Abstract

This paper presents an innovative improvement of the Constant On-Time (COT) control of DCM/CCM Boundary PFC Boost converter, to improve the total harmonic distortion (THD) of the input current at medium/light load. It is a wellknown fact that using a conventional COT control [1], the THD is increased with respect to a peak current-mode control due to the parasitic elements (e.g. C OSS power switch capacitance) that causes a negative offset in the inductor current shape [2], [3]-[4]. The Enhanced COT control (ECOT) introduced in [5] improves the THD, extending the power switch on-time T ON to compensate for the negative contribution. As a drawback, this control algorithm produces a minimum level of manageable output power, P OUT_MIN [6]. If the P OUT_MIN is higher than the power required by the load, the converter to keep the output voltage regulation stops the operation for some time (aka burst-mode [7]), significantly increasing the THD. The proposed improvement of the existing ECOT control method aims to overcome this issue.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call