Abstract

A study of the “before” and “after” ground-level S02 concentrations near the Muskingum River Plant of the American Electric Power System shows that the conversion from low to high stacks has accomplished marked reductions in ambient concentrations. These reductions are in reasonable agreement with theoretical calculations and are most apparent within 5 km of the source. EPA Standards are now being met in this area despite the presence of the 1440 MW power plant burning 5% sulfur fuel with no treatment of the stack gas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.