Abstract

A simplified formula for radiation streaming through bent ducts was previously derived by optics analogy, considering only components passing through the duct and without enormous preparatory calculations. Now, by taking account of deep penetrating component, the streaming formula is improved in order to estimate not only γ-ray flux but also neutron flux with accuracy, factor 2–3, applicable to preliminary shielding designs. Dose rates at the exit estimated by the improved formula are compared with experimental values. As for γ-ray evaluated values become conservative by improvement, while evaluated values were underestimated before improvement. Also for neutron, the discrepancy between the calculated values by the present formula and observed ones becomes within factor 2 after improvement from factor 3 before improvement. From these results, it is concluded that the improved formula is applicable to preliminary shielding designs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.