Abstract

The paper presents a method for identifying the parameters of a new model of induction motor. This model has two rotor loops in order to take into account the deep-bar effect and a non-linear leakage reactance which represents magnetic saturation effect. These phenomena cannot be neglected when induction motor dynamic characteristics have to be evaluated. The test method is simple and non-iterative. Only two locked-rotor tests at rated current and different frequency are required to derive the parameters of the two rotor loops. A further locked-rotor test at a suitable current value is necessary to determine the non-linear leakage reactance of the model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.