Abstract

The method for mouse vascularized heart transplantation have been described using suture and cuff techniques. Technical problems have limited its widespread use. Here, we describe our method of modified cervical heterotopic transplantation with the cuff technique. By using a smaller Teflon cuff (external diameter 0.6 mm, internal diameter 0.4 mm) and superfine-tip forceps, it became possible to directly pull the edge of the carotid artery and evert the proximal end of the artery over the cuff. Similarly, the external jugular vein could be easily everted over a 22-gauge cuff with this direct pulling method. By these modifications, the operation time was reduced. It usually takes 20 min for the donor harvest, 15 min for preparation of the cervical vessels, and 15 min for anastomosis. All procedures from the donor harvest through skin closure of the recipient mice can be completed within 1 hr, and ischemic time is within 25-40 min. This method can be used to investigate cyclophosphamide-induced tolerance and mechanisms of reperfusion injury.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.