Abstract
Introduction/Purpose: With increasing total ankle arthroplasty (TAA) being performed and a plethora of new survivorship data available, an updated literature review is needed to better understand the impact of different types of implants on the outcomes of TAA. The purpose of this study is to compare the outcomes of fixed vs mobile bearing TAAs in the literature. Methods: A comprehensive search of MEDLINE for all articles published between 2004 and 2023 was conducted with a minimum two-year mean follow-up. Two reviewers evaluated each study to determine whether it was eligible for inclusion and abstracted the data of interest. Meta-analytic pooling of group results across studies was performed, examining implant survival and component failure. Seventy-three implant groups met inclusion criteria (only 3rd and 4th generation implants), composed of STAR (20), Salto (mobile bearing) (10), Salto Talaris (11), Hintegra (8), Zimmer (6), INBONE II (6), INBONE I (4), Infinity (4), Cadence (4). 41 groups (56.2%) were implanted with mobile bearing devices, and 32 (43.8%) with fixed bearing implants. In total, 6498 subjects were included, with a mean age of 61.77 years and a mean BMI of 28.5 kg/m2. At a mean follow-up of 62.2 months, the overall reoperation rate was 21.13% and the metal component revision rate was 10.16%. Results: The mean follow-up of mobile bearing TAA studies (N =41) was 77.8 (range 24-188.4) months, and that of fixed bearing studies (N =32) was 45.3 (range 24-85.2) months. Multivariate analysis of bearing type, controlling for follow-up duration, found fixed bearing implants had statistically significantly higher metal component survival rates (fixed=96.1%, mobile=87.9%, p=.001); however, there were no statistically significant differences in rates of reoperation (fixed=17.0%, mobile=24.8%, p=.768). When examining specifically tibial and talar component failure rates, there was no statistically significant difference between bearing type (fixed tibial=1.46%, mobile tibial=2.95%, p=.472) (fixed talar=2.19%, mobile talar=2.79%, p=.966). Overall implant survival rates at one, two, five, and ten years were 96.4%, 96.0%, 92.7%, and 79.4%, respectively, and did not differ by bearing type (Table 1). Conclusion: Implant survival was statistically significantly better for 3rd and 4th generation fixed bearing TAAs as compared to mobile bearing TAAs, controlling for length of follow-up. There was no statistically significant difference in total reoperation rate. This suggests that fixed bearing implants may offer improved implant survival compared to mobile bearing implants, though further research is needed to confirm these findings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.