Abstract

Current regulation plays a key role in modern power electronic AC conversion systems. The most obvious strategy is to use a simple closed loop PI regulator. However it is well known that this approach cannot achieve zero steady state error because of the instability that inevitably occurs as the PI gains are increased to reduce this error. Linear analysis identifies that an AC load controlled by a PI regulator is a second order system with no theoretical stability limits as the gains are increased. Hence other factors must be responsible for the gain limits that are known to occur in practice. This paper revisits the use of a PI regulator to control AC currents and identifies that it is control loop delays that limit the PI regulator s gains. It is this limit that then constrains the controller s performance, particularly when the system feeds into backemf type loads. Methods are then presented to analytically determine the best possible gains that can be achieved within this constraint, and to improve the performance of a PI regulator by incorporating feedforward compensation of the load backemf into the control loop.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.