Abstract
Triclocarban (TCC) and triclosan (TCS) are used in a wide range of household and personal care products and have been the most frequently detected organic pollutants in both wastewater and surface water. This paper presented a rapid analytical method for simultaneous determination of TCC and TCS in wastewater. The method involves the extraction and cleanup of the target compounds by using silicon dioxide/polystyrene composite microspheres solid-phase extraction and detection with ultra-high-pressure liquid chromatography. Under the optimized conditions, the limits of detection were 0.028 μg/L and 0.040 μg/L for TCC and TCS, respectively. Under the concentrations of the spiking level ranging from 0.100 μg/L to 2.000 μg/L, the spiked recoveries of TCC and TCS in wastewater samples achieved in the range of 89.5–102.8% with RSD below 6.3% for TCC and 95.5–103.6% with RSD below 6.9% for TCS. This method was successfully used in monitoring the water samples from three traditional wastewater treatment plants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.