Abstract

In high power high performance AC drive industrial applications, multilevel inverters have established their importance, as they can synthesise output waveform with improved harmonic spectrum. In this paper, an improved synchronisation and symmetrical SVPWM algorithm is proposed for three-level inverter in overmodulation region for better utilisation of DC bus and to reduce harmonic distortion. The performance analysis of the proposed algorithm is compared with SHEPWM and STPWM for three-level voltage source inverter in terms of THD of line voltage and motor current along with fundamental component of the line voltage. It is shown that the proposed algorithm gives improved results compared to SHEPWM and STPWM algorithms. The algorithm is also verified experimentally on a constant v/f drive fed from IGBT-based voltage source inverter using Motorola power PC (MPC8240) based embedded controller.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.