Abstract

To test the feasibility and performance of dual-energy computed tomography (DECT) in foot arteriography of diabetic patients, where contrast medium is largely reduced within the small vessels. A total of 50 diabetic patients were enrolled prospectively, where DECT was acquired immediately after the CT angiography (CTA, group A) of the lower extremity. Two images were derived from the DECT data, one optimal virtual monochromatic image (VMI, group B) and one fusion image (group C), both of which were compared against the CTA image for visualising the foot arteries. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were evaluated. The arterial course and contrast were graded each using a five-point scale. The clarity of small vessel depiction was quantified by comparing the number of plantar metatarsal arteries found in the maximum intensity projection image. The median CNRs and SNRs obtained in group B were approximately 45% and 20% higher than those in groups A and C, respectively (p<0.05). Group B also received higher subjective scores on the posterior tibial artery and the foot arteries (all >3) than groups A and C. The number of visible branches of the plantar metatarsal arteries was found to be substantially higher (p<0.05) in group B (median=6) than in groups A (median=2) and C (median=4). DECT was found to be superior to conventional CTA in foot arteriography, and beyond the lower extremity, it might be a general favourable solution for imaging regions with small vessels and reduced contrast medium.