Abstract
Phenacyl esters of C12-C22 fatty acids were separated on Separon SGX C18 column, using a gradient elution with methanol-acetonitrile-water. The proposed gradient showed better resolution of the critical pairs C18:3-C14:0, C16:1-C20:4, and C16:0-C18:1 than the gradient elution with methanol-water or acetonitrile-water, or than the isocratic elution with methanol-acetonitrile-water. The optimum volume concentration (83%) of the sum of both methanol and acetonitrile was maintained constant for 35 min; in this period the acetonitrile concentration decreased linearly from the initial 42-60% to 0% while the methanol concentration increased from the initial 41-23% to 83% at the same rate. After 35 min the elution was completed with a methanol-water gradient. The whole analysis can be performed within 63 min at a flow rate 1 ml/min.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Collection of Czechoslovak Chemical Communications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.