An improved sample preparation procedure for analysis of carcinogenic ethyl carbamate (EC) in wine by GC–MS–SIM is proposed. Differences over AOAC reference procedure were: (1) use of EC-d5 as internal standard instead of less similar propyl carbamate; (2) extraction by diethyl ether instead of more toxic dichloromethane, and (3) concentration by vacuum automated parallel evaporation instead of more time and work consuming rotary evaporation. Mean recovery was 104.4%, intraday precision was 6.7% (3.4μgL−1) and 1.7% (88.5μgL−1), regression coefficient was 0.999 in the linear working range of 3–89μgL−1, and limits of detection and quantification were 0.4 and 1.2μgL−1. Applicability was demonstrated by analysis (in triplicate) of 5 wine samples. EC concentration ranged from 5.2±0.2 to 29.4±1.5μgL−1. The analytical method is selective, accurate, repeatable, linear, and has similar method performance as the reference method along with the several mentioned advantages.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.