Abstract

In recent times, reduced switch count multilevel inverter (RSC-MLI) has become an emerging area of research in power electronic converters. To control these RSC-MLI topologies, various novel modulation schemes are reported. Multi-reference is one of such modulation scheme reported for various RSC topologies, such as T-type. However, the performance of this conventional scheme results in high total harmonic distortion (THD) in line voltages, when compared with the conventional level shifted pulse-width modulation scheme. This observation is clearly presented in this study and the reason for its degraded THD performance has been deeply discussed. To alleviate this problem, a modified multi-reference dual-carrier modulation technique with multiple references and two carriers is proposed. To implement this proposed modulation technique, an alternate carrier and modulation signals arrangement with multiple carriers and single reference is also presented. Finally, a comparative THD performance of the proposed and conventional modulation schemes is carried out on a five-level T-type MLI and obtained simulation results are validated experimentally.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.