The pH of boiler feedwater is raised by the addition of ammonia to a level at which corrosion of the boiler is limited and consequently the measurement of pH is of primary operational interest. It is considered necessary to refer this measurement to a standard temperature of 25 °C because under conditions of varying sample temperatures, some pH meters will record changes in pH that are solely due to the effects of temperature on the chemical equilibrium of the ammonia-dosed water. At present, readings at a reference temperature can be made by controlling the sample temperature or by inclusion of additional compensation circuits in the pH meter. An attractive alternative to either of these methods is the use of self-temperature-compensating electrodes whose physico-chemical properties compensate for the temperature-induced changes in the pH of the sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.