Abstract

This study aimed to compare the accuracy of relative cerebral blood volume (rCBV) and percentage signal recovery (PSR) obtained from high flip-angle dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) sequences with and without contrast agent (CA) preload for presurgical discrimination of brain glioblastoma and lymphoma. Consecutive 336 patients (glioblastoma, 236; PCNSL, 100) were included. All the patients underwent DSC-PWI on 3.0-T magnetic resonance units before surgery. The rCBV and PSR with preloaded and non-preloaded CA were measured. The means of the continuous variables were compared using Welch's t-test. The diagnostic accuracies of the individual parameters were compared using the receiver operating characteristic curve analysis. The rCBV was higher with preloaded CA than with non-preloaded CA (glioblastoma, 10.20 vs. 8.90, p = 0.020; PCNSL, 3.88 vs. 3.27, p = 0.020). The PSR was lower with preloaded CA than with non-preloaded CA (glioblastoma, 0.59 vs. 0.90; PCNSL, 0.70 vs. 1.63; all p < 0.001). Regarding the differentiation of glioblastoma and PCNSL, the AUC of rCBV with preloaded CA was indistinguishable from that of non-preloaded CA (0.940 vs. 0.949, p = 0.703), whereas the area under the curve of PSR with preloaded CA was lower than non-preloaded CA (0.529 vs. 0.884, p < 0.001). With preloaded CA, diagnostic performance in differentiating glioblastoma and PCNSL did not improve for rCBV and it was decreased for PSR. Therefore, high flip-angle non-preload DSC-PWI sequences offer excellent accuracy and may be of choice sequence for presurgical discrimination of brain lymphoma and glioblastoma. High flip-angle DSC-PWI using non-preloaded CA may be an excellent diagnostic method for distinguishing glioblastoma from PCNSL. • Differentiating primary central nervous system lymphoma and glioblastoma accurately is critical for their management. • DSC-PWI sequences optimised for the most accurate CBV calculations may not be the optimal sequences for presurgical brain tumour diagnosis as they could be masquerading leakage phenomena that may provide interesting information in terms of differential diagnosis. • High flip-angle non-preloaded DSC-PWI sequences render the best accuracy in the presurgical differentiation of brain lymphoma and glioblastoma.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.