Abstract

Phase measurement deflectometry (PMD) is an excellent method for high-precision optical surface measurement; through the simple system structure, accuracy comparable to that of interference methods can be realized. The key of PMD is to solve the ambiguity between the surface shape and normal vector. Considering all kinds of methods, the binocular PMD method is undoubtedly a method with a very simple system structure and can be easily applied to complex surfaces, such as free-form surfaces. However, this method relies on a large screen with high accuracy, which not only increases the weight of the system, but also reduces the flexibility of the system, and manufacturing errors in the large-size screen can easily become error sources. In this Letter, we have made some improvements based on the traditional binocular PMD. At first, we try to replace the large screen with two small screens to increase the flexibility and accuracy of the system. Further, we replace one small screen with a single point to simplify the system structure. Experiments show that the proposed methods not only improve the system flexibility and reduce the complexity, but can also achieve high measurement accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.