Abstract

Many control schemes have been proposed for induction motors, which are in themselves highly complex non-linear and sometimes internally unstable systems. One of the most accurate control schemes is encodered rotor flux orientated vector control. The advantages and disadvantages of this control are well known and several variations, or reduced vector schemes, have been proposed. This study introduces an improved encoderless scalar, or approximated vector, control method for induction machines which can be applied to general purpose applications that do not require the most precise control. The proposed method overcomes practical difficulties and is suitable for industrial applications. The slip compensated stator flux linkage oriented scheme proposed in this study does not require flux estimation or a speed sensor, only requiring nameplate data, stator current and stator resistance measurement, which can easily be determined at start-up. Simulation and experimental investigations including field weakening operation and the effect of stator resistance variation demonstrate the improved performance of the new scheme compared to previous open loop V/Hz and stator resistive compensated schemes especially at low rotor speeds.