Abstract

A new measurement of the reactor antineutrino flux and energy spectrum by the Daya Bay experiment is reported. With a live time of 621 days, more than 1.2 million inverse beta decay (IBD) candidates were collected by eight antineutrino detectors (ADs) deployed in two near (560 m and 600 m flux-weighted baselines) and one far (16400 m flux-weighted baseline) underground experimental halls. The IBD yield was measured and the ratio to the predicted flux using the Huber+Mueller (ILL+Vogel) model was determined to be 0.946 ± 0.020 (0.992 ± 0.021). A 2.9 σ deviation was found in the measured IBD positron energy spectrum compared to the predictions. In particular, an excess of events in the region of 4-6 MeV was found with a local significance of 4.4 σ.