Abstract

A new Kolsky tension bar has been re-designed and developed at Sandia National Laboratories, CA. The new design uses the concept that a solid striker is fired to impact an end cap attached to the open end of the gun barrel to generate dynamic tensile loading. The gun barrel here serves as part of the loading device. The incident bar that is connected to the gun barrel and the transmission bar follow the design similar to the Kolsky compression bar. The bar supporting and aligning systems are the same as those in the Kolsky compression bar design described by Song et al (2009 Meas. Sci. Technol. 20 115701). Due to the connection complication among the gun barrel, bars and specimen, stress-wave propagation in the new Kolsky tension bar system is comprehensively analyzed. Based on the stress-wave analysis, the strain gage location on the incident bar needs to be carefully determined. A highly precise laser-beam measurement system is recommended to directly measure the displacement of the incident bar end. Dynamic tensile characterization of a 4330-V steel using this new Kolsky tension bar is presented as an example.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.