Abstract

The results of examination of the condition of the heart using an electrocardiograph are generally presented in an ecg paper. Using ecg paper because in the paper there are boxes that are used as guidelines for calculating wave amplitude and wave duration. If the required amplitude is information on peak amplitude and wave morphology information, then the duration is information on the value of segment duration, interval duration, and heart rate. As is known in the ECG paper the results of the examination that only some information is presented, so information that does not yet exist must be calculated manually using existing boxes. This manual calculation requires time and accuracy, so that this waiting time can cause the patient's disease stage to increase, and on the other hand that the lack of accuracy of the calculation can cause misdiagnosis. This study aims to provide information on clinical standard cardiac examination results using Electrocardiograph discrete (ECGd) and standard Electrocardiograph (ECGs). In ECGd, the leads of the heart signal are sampled at a frequency of 250 Hz so that it becomes discrete data. Maximum filtering on 1.6 mV treshold data discrete peak R is obtained in each cycle. The PQRST algorithm method is used to get the PQST peak and duration parameters. The results showed that the percentage of the amount of information from the ECGd examination was 82.4% while the results of the ECGs examination were 25.4%

Highlights

  • The results of examination of the condition of the heart using an electrocardiograph are generally presented in an ecg paper

  • In Pacemaker there are three impulse triggers namely SA node which has a frequency of 60-100 bpm, AV node which has a frequency of 40-60 bpm, and Purkinje fiber which has a frequency of 20- 40 bpm [1]

  • An impulse spark originating from the SA node works to cause an action potential, but if the SA node experiences a dysfunction it will be replaced by the AV node, as well as if the AV node is dysfunctional it will be replaced by Purkinje fiber [4]

Read more

Summary

Introduction

The results of examination of the condition of the heart using an electrocardiograph are generally presented in an ecg paper. The impulse trip as shown in figure 3 will generate a potential difference wave (mV) as a function of time (ms), ie a continuous analog signal [5]. This periodic impulse spark from Pacemaker will cause cycles containing waves.

Objectives
Methods
Results
Conclusion