Abstract

BackgroundMART-1, Melan-A, and Tyrosinase have shown encouraging results for evaluation of melanoma micrometastases in sentinel lymph nodes, as compared to conventionally used S-100 protein and HMB-45. To achieve higher sensitivity, some studies recommend evaluation of three sections, each at intervals of 200 μ. This would mean, routine staining of three adjacent sections in each of the three clusters at intervals of 200 μ, requiring nine slides resulting in added expense. If a cocktail of these antibodies could be used, only one section would be required instead of three generating significant cost savings.MethodsWe prepared a combination of monoclonal antibodies to these three immunomarkers in optimized dilutions (MART-1, clone M2-7C10, dilution 1:500; Melan-A, clone A103, dilution 1:100; and Tyrosinase, clone T311, dilution 1:50) and designated it as 'MCW melanoma cocktail'. Formalin-fixed paraffin-embedded tissue sections of sentinel lymph nodes from patients with cutaneous melanoma, without macro-metastases were evaluated with this cocktail.ResultsMelanoma micrometastases were easily detectable with the cocktail in 41 out of 188 slices (8/24 cases). The diagnostic accuracy amongst five pathologists did not show statistically significant difference. Out of 188 slices, 78 had adjacent sections immunostained individually with MART-1 and Melan-A during our previous study. Of these 78 slices, 21 were positive for melanoma micrometastases with MART-1 and Melan-A individually. However, the adjacent section of these slices immunostained with the cocktail detected metastases in four additional slices. Thus, MART-1 and Melan-A could not detect melanoma micrometastases individually in 16% (4/25) of slices positive with the cocktail. Benign capsular nevi were immunoreactive for the cocktail in 4.8% (9/188) slices. All 81 slices of negative test controls (sentinel lymph nodes of mammary carcinoma) were interpreted correctly as negative for melanoma micrometastases.ConclusionsThe melanoma cocktail facilitated easy interpretation of melanoma micrometastases in sentinel lymph nodes with high interobserver agreement. There was improvement in detection rate with the cocktail as compared to MART-1 and Melan-A individually. Furthermore, this approach facilitates cost savings.

Highlights

  • MART-1, Melan-A, and Tyrosinase have shown encouraging results for evaluation of melanoma micrometastases in sentinel lymph nodes, as compared to conventionally used S-100 protein and HMB-45

  • The melanoma cocktail facilitated easy interpretation of melanoma micrometastases in sentinel lymph nodes with high interobserver agreement

  • We had demonstrated higher diagnostic accuracy in detecting and diagnosing melanoma micrometastases in sentinel lymph node using monoclonal antibodies to MART-1 and Melan-A in comparison to the traditionally used immunohistochemical markers, S-100 protein (S-100) and HMB-45 [6]

Read more

Summary

Introduction

MART-1, Melan-A, and Tyrosinase have shown encouraging results for evaluation of melanoma micrometastases in sentinel lymph nodes, as compared to conventionally used S-100 protein and HMB-45. Some studies recommend evaluation of three sections, each at intervals of 200 μ This would mean, routine staining of three adjacent sections in each of the three clusters at intervals of 200 μ, requiring nine slides resulting in added expense. Because of significant morbidity associated with the procedure, regional lymphadenectomy has been generally recommended only for patients with evidence of regional lymph node involvement [1]. We had demonstrated higher diagnostic accuracy in detecting and diagnosing melanoma micrometastases in sentinel lymph node using monoclonal antibodies to MART-1 (clone M2-7C10) and Melan-A (clone A103) in comparison to the traditionally used immunohistochemical markers, S-100 protein (S-100) and HMB-45 [6]. A monoclonal antibody to a third melanoma immunomarker, Tyrosinase (clone T311), showed an immunostaining pattern similar to MART-1 and Melan-A [13]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.