Abstract
This paper proposes an improved type of the Hybrid-Parallel Power-Factor-Correction (HP-PFC) converter. It has the advantage of a higher efficiency and improved input current waveform. This advantage achieved through changing new charging path of the bulk capacitor and balancing the power flow from the two transformers to the output. This new circuit has been analyzed using MATLAB/Simulink and confirmed with experiment. As a conclusion, it is confirmed that this improved HP-PFC converter complies with the severe regulation of IEC61000-3-2 Class D. Moreover, a high efficiency of 90% is achieved for 15 V/6 A output power under the worldwide line voltage conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.