Abstract
The present author’s general correlation for condensation in mini and macro channels which has been verified with an extreme range of data was further evaluated at quality x close to 1. Large deviations were found at quality x ≥ 0.99. The correlation was modified to improve the accuracy in this range of quality. The improved correlation has a MAD (mean absolute deviation) of 22.1% in this range of quality compared to 95% in the published correlation. This improvement is important for the calculation of heat transfer in the condensation of superheated vapor as it requires the value of the heat transfer coefficient at quality x = 1. The new correlation is presented together with a comparison of data. Various aspects of the correlation are discussed. Results of the comparison of all data with the new correlation as well as other correlations are given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.