Summary Laboratory-gas dynamic throughput testing indicates that each injection-operated gas lift valve (GLV) often does not open fully in actual operation, mainly because of the bellows-stacking phenomenon. This paper addresses such issues and recommends a simple but effective solution. A modified design for the GLV seat was created to reduce the required stem travel to generate a flow area equal to the port area. This paper details the new design, theoretical calculations, and experimental results. Theoretical calculations showed that the minimum stem travel for the modified design improved from 10 to 58% compared with using a conventional sharp-edged seat. The experimental results showed that for the same amount of stem travel, the modified design provides a larger flow rate than the sharp-edged seat.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.