Abstract

An improved method was developed for the quantitative determination of daminozide. This new method combines the alkaline hydrolysis and distillation steps of the PAM II method for daminozide with the derivatization, cleanup, and gas chromatographic determination steps of the Wright method for unsymmetrical dimethyl hydrazine (UDMH). The minimum detectable level is 0.05 ppm. Recoveries range from 85 to 110% when daminozide is added at 0.1 to 1.0 ppm, and are generally 40% at the 0.05 ppm level. A variety of domestic and imported products were analyzed by this improved method and daminozide was detected in 33 of the 98 samples analyzed. Levels detected ranged from a trace amount to 0.80 ppm. The identity of UDMH hydrazone was confirmed by mass spectrometry in many samples, thus confirming the presence of daminozide. Two samples containing daminozide were analyzed independently by a second laboratory and the findings were closely duplicated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.