Abstract

A new design for an electro-osmotic flow (EOF) driven micropump was fabricated. Considering thermal management applications, three different types of micropumps were tested using multiple liquids. The micropumps were fabricated from a combination of materials, which included: silicon-polydimethylsiloxane (Si-PDMS), Glass-PDMS, or PDMS-PDMS. The flow rates of the micropumps were experimentally and numerically assessed. Different combinations of materials and liquids resulted in variable values of zeta-potential. The ranges of zeta-potential for Si-PDMS, Glass-PDMS, and PDMS-PDMS were −42.5–−50.7 mV, −76.0–−88.2 mV, and −76.0–−103.0 mV, respectively. The flow rates of the micropumps were proportional to their zeta-potential values. In particular, flow rate values were found to be linearly proportional to the applied voltages below 500 V. A maximum flow rate of 75.9 μL/min was achieved for the Glass-PDMS micropump at 1 kV. At higher voltages nonlinearity and reduction in flow rate occurred due to Joule heating and the axial electro-osmotic current leakage through the silicon substrate. The fabricated micropumps could deliver flow rates, which were orders of magnitude higher compared to the previously reported values for similar size micropumps. It is expected that such an increase in flow rate, particularly in the case of the Si-PDMS micropump, would lead to enhanced heat transfer for microchip cooling applications as well as for applications involving micrototal analysis systems (μTAS).