Abstract


 
 
 Vibration analysis is perhaps the longest serving technology used in condition monitoring. It is usually assumed that higher sampling rates improve fault detection due to the increased bandwidth of the acquisition. That said, increased bandwidth may decrease the signal to noise, impairing fault detection. Alternatively, if the fault features’ bandwidth is greater than the system bandwidth, the fault cannot be observed. One tool of vibration analysis is the Time Synchronous Average (TSA) analysis. Statistics of the TSA itself can be used as a fault feature, or statistics based on analysis performed on the TSA (energy operator, residual analysis, amplitude/frequency modulation analysis) are used as fault features. Additionally, the computation of the TSA requires a tachometer signal for zero crossing, which has its own bandwidth effect on the TSA analysis. This paper discusses bandwidth control techniques to improve fault detection using the TSA. The techniques are validated using real world pinion data. These techniques have other advantages for embedded condition monitoring systems.
 
 

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.