The efficiency, durability, and health of the energy storage system components depend on controlling the power flow subjected to proper operational constraints. It is achieved by energy management algorithm (EMA). Conventional EMAs restrict the ultracapacitor (UC) operation to a reference voltage to prevent it from overcharging/undercharging. This leads to very narrow utilization of the UC voltage range. However, UC voltage can safely be varied from zero to maximum-rated voltage. Rather than employing a UC voltage control loop that operates concurrently to transient load demand, a time-share-based approach has been used for UC charging/discharging. Hence, EMA has been modified in the present work by utilizing the UC voltage band instead of a UC reference voltage, which increases its power delivery capacity by approximately two to four times. In this paper, the proposed EMA improves the transient performance of the system and reduces the UC size. An experimental prototype of the system is designed, and the proposed EMA is tested in the different operating regions for validation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.