Abstract

The dynamic filters of the KEK 12 GeV PS were improved in the voltage ripple detector, in the control system and in the power-up of the PWM and B-class amplifiers. Especially, a use of new developed voltage ripple detector was able to change from the former feed forward system to the feed back control system. As the results, the low frequency ripple voltage across the magnet coil (< 300 Hz) could be reduced to less than -26 db to the inputs in the B, QF and QD magnet power supply and the current ripple is considered to be about 8 × 10-6 at flat top current 2,850 A during extraction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.