Abstract

A DC/AC interface inverter for a high-frequency space power distribution system that uses dual asymmetrical resonant bridges is examined. Compared to the conventional approach in which two symmetrical bridges are used, the asymmetrical bridges arrangement offers better use of the installed kVA rating and efficiency of the inverter system. A simplified approach for modeling the inverter system in steady-state is presented, and a criteria to select the resonant components is given. A detailed simulation is performed for the following: a symmetrical inverter system with a resistive load, an asymmetrical inverter system with a resistive load, and an asymmetrical inverter system with the type-1A AC/DC converter load. >