A study has been carried out of the electron-optical properties of improved design of the cylindrical mirror energy analyzer. Both external and internal electrodes of the analyzer are divided into three isolated parts, whereby the potentials on the individual parts can be regulated independently from each other. In symmetric operating mode at identical potentials on the side parts of the electrodes, a significant increase has been obtained in resolving power and light-gathering power of the analyzer compared to the standard design of the cylindrical mirror. In asymmetric operating mode, which is implemented in a linear potential distribution on the external electrode, the conditions have been found under which the linear dispersion of the analyzer increases several times.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.