Abstract

Despite using different electrode positions, "conventional" external DC cardioversion in patients with atrial fibrillation is ineffective in 6%-50% of cases. An alternative when DC cardioversion is not successful is low energy internal cardioversion, which is performed at increased risk. We tested the hypothesis that optimization of electrode pad position under fluoroscopy to encompass as much atrial muscle as possible might improve the success rate of external cardioversion and thus minimize the need for internal cardioversion. Fifteen (9 males, 6 females) patients (age: 54 +/- 15 years, weight: 124 +/- 35 kg) with chronic atrial fibrillation (> 8 weeks) who had undergone unsuccessful conventional external cardioversion entered the study. Repeat conventional external cardioversion with electrodes in standard (right anterior and left posterior) positions was followed by "optimized" external cardioversion by positioning electrodes under fluoroscopy (using metallic markers). In case of failure, internal cardioversion was performed. All 15 patients had undergone unsuccessful conventional external cardioversion with 360-J shocks. Eight patients (group A) reverted to sinus rhythm with one or two 360-J shocks using fluoroscopy-guided pad placement (53%). Six of the remaining 7 (86%) patients (group B) had successful internal cardioversion with biphasic shocks (12 +/- 3 J). The body weight and body mass index were statistically lower in group A vs group B (106 +/- 27 vs 145 +/- 33 kg, p = 0.03 and 35 +/- 8 vs 45 +/- 8 kg/m2, P = 0.48, respectively). There was no statistically significant in age, height, body surface area, duration of atrial fibrillation, amiodarone therapy, ejection fraction, or underlying heart disease. Unsuccessful external DC cardioversion, in some patients, is in part due to suboptimal conventional positioning of electrode pads that can be improved under fluoroscopic guidance by achieving the best possible vector encompassing the right and left atria. The optimized external cardioversion technique may minimize the need for internal cardioversion, which remains an effective approach when external cardioversion fails.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.