Abstract
[EN] Different electronic interfaces have been proposed to measure major parameters for the characterization of quartz crystal microbalance (QCM) during the last two decades. The measurement of the adequate parameters of the sensor for a specific application is very important, since an error in this measure can lead to an error in the interpretation of the results. The requirements of the system of characterization depend on the application. In this thesis we propose two characterization systems for two types of applications that involve the majority of sensor applications: 1) Characterization of materials under variable damping conditions and 2) Detection of substances with high measurement resolution. The proposed systems seek to solve the problems detected in the systems currently in use. For applications in which the sensor damping varies during the experiment, we propose a system based on a new configuration of the technique of automatic capacitance compensation (ACC). This new configuration provides the measure of the series resonance frequency, the motional resistance and the parallel capacitance of the sensor. Moreover, it allows an easy calibration of the system that improves the precision in the measurement. We show the experimental results for 9 and 10 MHz crystals in fluid media, with different capacitances in parallel, showing the effectiveness in the capacitance compensation. The system presents some deviation in frequency with respect to the series resonance frequency, as measured with an impedance analyser. These deviations are due to the non-ideal, specific behaviour of some of the components of the circuit. A new circuit is proposed as a possible solution to this problem. For high-resolution applications we propose an integrated platform to characterize high-frequency acoustic sensors. The proposed system is based on a new concept in which the sensor is interrogated by means of a very stable, low-noise external source at a constant frequency, while the changes provoked by the charge in the phase of the sensor are monitored. The use of high-frequency sensors enhances the sensitivity of the measure, whereas the design characterization system reduces the noise in the measurement. The result is an improvement in the limit of detection (LOD). This way, we achieve one of the challenges in the acoustic high-frequency devices. The validation of the platform is performed by means of an immunosensor based in high fundamental frequency QCM crystals (HFF-QCM) for the detection of two pesticides: carbaryl and thiabendazole. The results obtained for carbaryl are compared to the results obtained by another high-frequency acoustic technology based in Love sensors, with the optical technique based in surface plasmonic resonance and with the gold standard technique Enzyme Linked Immunoassay (ELISA). The LOD obtained with the acoustic sensors HFF-QCM and Love is similar to the one obtained with ELISA and improves by one order of magnitude the LOD obtained with SPR. The conceptual ease of the proposed system, its…
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.