Some improvements are presented in this paper to the previously introduced automated multi-range multipliers system. These multipliers; range resistors are selected automatically by using electronic relays controlled by a micro-controller that connects the suitable multiplier to the thermal voltage converter to calibrate the required ac voltage. The modifications done on the old system are mainly in used resistors and connectors. The ac–dc transfer differences for the improved and the old multipliers systems combined with the same thermal converter are determined automatically against another standard thermal voltage converter. The obtained ac–dc differences results and their repeatability; Type A for both systems are compared to evaluate the performance of the new one. The new system introduces a better performance, smaller ac–dc differences and Type A, especially in the high voltage and frequency ranges.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.