Abstract
Capacitor-current-feedback active damping method is commonly used in LCL-filtered grid-connected inverters, which attenuates the resonance peak by emulating a virtual resistor in parallel with the filter capacitor. Taking the digital control delay into account, the emulation component becomes frequency-dependent, and it will turn negative when the filter resonance frequency becomes higher than one-sixth of the sampling frequency, resulting in the inconsistent stability requirement. Due to the variation of grid impedance, the filter resonance frequency will vary in a wide range, and the inconsistent stability requirement may occur, which will pose a challenge to the inverter stability. In this paper, the stability of digitally controlled LCL-filtered inverter is studied first, and a phase lag compensator is introduced to ensure the stability requirement keeps consistent even if the filter resonance frequency reaches the Nyquist frequency. Thus the stability-robustness of the inverter to the grid impedance variation is improved. Finally, the validation of the proposed compensation method is verified by simulation and experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.