Abstract
This paper presents a technique for imposing maximum length scale on features in continuum topology optimization. The design domain is searched and local constraints prevent the formation of features that are larger than the prescribed maximum length scale. The technique is demonstrated in the context of structural and fluid topology optimization. Specifically, maximum length scale criterion is applied to (a) the solid phase in minimum compliance design to restrict the size of structural (load-carrying) members, and (b) the fluid (void) phase in minimum dissipated power problems to limit the size of flow channels. Solutions are shown to be near 0/1 (void/solid) topologies that satisfy the maximum length scale criterion. When combined with an existing minimum length scale methodology, the designer gains complete control over member sizes that can influence cost and manufacturability. Further, results suggest restricting maximum length scale may provide a means for influencing performance characteristics, such as redundancy in structural design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.