Abstract
ObjectivesThis study reports a comparative assessment of the hemodynamic relevance of myocardial bridges (MB) using two modalities of fractional flow reserve (FFR), with and without concomitant inotropic challenge. BackgroundExtravascular coronary compression by means of MB is modulated by myocardial inotropism and causes intracoronary systolic pressure overshooting and negative systolic gradients across the MB. The former characteristic suggests that adequate hemodynamic assessment of MB should include inotropic stimulation. The latter characteristic might interfere with FFR by decreasing the mean pressure gradient. MethodsWe compared the hemodynamic relevance of 12 lone MB in symptomatic patients using conventional (mean) and diastolic FFR. Diastolic FFR was obtained from post-processed, digitally acquired electrocardiogram and pressure signals. Previously validated cut off values of 0.75 (mean FFR) and 0.76 (diastolic FFR) for hemodynamic relevance were used. Measurements were performed at baseline and after incremental intravenous dobutamine doses. ResultsFractional flow reserve decreased during dobutamine challenge: mean FFR was 0.90 ± 0.04 at baseline and 0.84 ± 0.06 after dobutamine (p = 0.0008); similarly, diastolic FFR was 0.88 ± 0.05 and 0.77 ± 0.10 before and after dobutamine, respectively (p = 0.0006). Diastolic FFR identified hemodynamic relevance in five patients, whereas mean FFR did so in only one patient. The discrepancy between mean FFR and diastolic FFR increased with dobutamine challenge: the ratio of mean FFR/diastolic FFR was 1.03 at baseline and 1.09 after dobutamine (p = 0.02). During the administration of dobutamine, the discrepancy was inversely related to the systolic pressure gradient (r = 0.58, p = 0.04). ConclusionsPhysiologic assessment of MB should include dobutamine challenge. Because the overshooting of systolic pressure interferes with and is a cause of error in FFR measurements based on mean pressures, diastolic FFR appears to be the technique of choice for MB assessment, whereas mean FFR should be used with caution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.