Abstract

In thoracolumbar deformity surgery, anterior-only approaches are used for reconstruction of anterior column failures. It is generally advised that vertebral body replacements (VBRs) should be preloaded by compression. However, little is known regarding the impact of different techniques for generation of preloads and which surgical principle is best for restoration of lordosis. Therefore, the authors analyzed the effect of different surgical techniques to restore spinal alignment and lordosis as well as the ability to generate axial preloads on VBRs in anterior column reconstructions. The authors performed a laboratory study using 7 fresh-frozen specimens (from T-3 to S-1) to assess the ability for lordosis reconstruction of 5 techniques and their potential for increasing preloads on a modified distractable VBR in a 1-level thoracolumbar corpectomy. The testing protocol was as follows: 1) Radiographs of specimens were obtained. 2) A 1-level corpectomy was performed. 3) In alternating order, lordosis was applied using 1 of the 5 techniques. Then, preloads during insertion and after relaxation using the modified distractable VBR were assessed using a miniature load-cell incorporated in the modified distractable VBR. The modified distractable VBR was inserted into the corpectomy defect after lordosis was applied using 1) a lamina spreader; 2) the modified distractable VBR only; 3) the ArcoFix System (an angular stable plate system enabling in situ reduction); 4) a lordosizer (a customized instrument enabling reduction while replicating the intervertebral center of rotation [COR] according to the COR method); and 5) a lordosizer and top-loading screws ([LZ+TLS], distraction with the lordosizer applied on a 5.5-mm rod linked to 2 top-loading pedicle screws inserted laterally into the vertebra). Changes in the regional kyphosis angle were assessed radiographically using the Cobb method. The bone mineral density of specimens was 0.72 ± 22.6 g/cm(2). The maximum regional kyphosis angle reconstructed among the 5 techniques averaged 9.7°-16.1°, and maximum axial preloads averaged 123.7-179.7 N. Concerning correction, in decreasing order the LZ+TLS, lordosizer, and ArcoFix System outperformed the lamina spreader and modified distractable VBR. The order of median values for insertion peak load, from highest to lowest, were lordosizer, LZ+TLS, and ArcoFix, which outperformed the lamina spreader and modified distractable VBR. In decreasing order, the axial preload was highest with the lordosizer and LZ+TLS, which both outperformed the lamina spreader and the modified distractable VBR. The technique enabling the greatest lordosis achieved the highest preloads. With the ArcoFix System and LZ+TLS, compression loads could be applied and were 247.8 and 190.6 N, respectively, which is significantly higher than the insertion peak load and axial preload (p < 0.05). Including the ability for replication of the COR in instruments designed for anterior column reconstructions, the ability for lordosis restoration of the anterior column and axial preloads can increase, which in turn might foster fusion.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call