Abstract
In this work, we have carried out a dielectric study to determine the effect of tobacco smoke on the rat corneal function. Measurements were performed over the frequency range of 500 Hz–100 kHz in air and at the temperature of 35 °C. The frequency dependencies of the loss tangent for both healthy and smoky cornea exhibit two peaks with different width occurring as a narrow at 2 kHz and a broad at around 16 kHz. The distribution parameter α at 2 kHz has a value of about 0.3, which increases to 0.6 at 16 kHz. The magnitude of the permittivity decrement at 2 and 16 kHz is about two and four times higher, respectively, for the smoky cornea than that for the healthy one. These dielectric studies indicate that the present method is useful in detection of the effect of tobacco smoke exposure on the corneal behavior.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.