Abstract

This study aimed to investigate the impact of calcific (Ca) on the efficacy of coronary computed coronary angiography (CTA) in evaluating plaque burden (PB) and composition with near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) serving as the reference standard. Sixty-four patients (186 vessels) were recruited and underwent CTA and 3-vessel NIRS-IVUS imaging (NCT03556644). Expert analysts matched and annotated NIRS-IVUS and CTA frames, identifying lumen and vessel wall borders. Tissue distribution was estimated using NIRS chemograms and the arc of Ca on IVUS, while in CTA Hounsfield unit cut-offs were utilized to establish plaque composition. Plaque distribution plots were compared at segment-, lesion-, and cross-sectional-levels. Segment- and lesion-level analysis showed no effect of Ca on the correlation of NIRS-IVUS and CTA estimations. However, at the cross-sectional level, Ca influenced the agreement between NIRS-IVUS and CTA for the lipid and Ca components (p-heterogeneity < 0.001). Proportional odds model analysis revealed that Ca had an impact on the per cent atheroma volume quantification on CTA compared to NIRS-IVUS at the segment level (p-interaction < 0.001). At lesion level, Ca affected differences between the modalities for maximum PB, remodelling index, and Ca burden (p-interaction < 0.001, 0.029, and 0.002, respectively). Cross-sectional-level modelling demonstrated Ca's effect on differences between modalities for all studied variables (p-interaction ≤ 0.002). Ca burden influences agreement between NIRS-IVUS and CTA at the cross-sectional level and causes discrepancies between the predictions for per cent atheroma volume at the segment level and maximum PB, remodelling index, and Ca burden at lesion-level analysis. Coronary calcification affects the quantification of lumen and plaque dimensions and the characterization of plaque composition coronary CTA. This should be considered in the analysis and interpretation of CTAs performed in patients with extensive Ca burden. Coronary CT Angiography is limited in assessing coronary plaques by resolution and blooming artefacts. Agreement between dual-source CT angiography and NIRS-IVUS is affected by a Ca burden for the per cent atheroma volume. Advanced CT imaging systems that eliminate blooming artefacts enable more accurate quantification of coronary artery disease and characterisation of plaque morphology.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.