Abstract

ObjectivesMain objective: To compare the effectiveness for checking surgical margins between SPECT-portable and mammography of the piece (RxM). Secondary objectiveTo standardize a pre-operative protocol using SPECT-portable and to evaluate the time required in the use of this technique. Material and methodsProspective longitudinal study with 36 patients (39 lesions) diagnosed with breast cancer (CM) with criteria for SNOLL/ROLL.A pre-surgical study of the tumor lesion was performed, after the eco-guided administration of 99mTc-nanocolloids of albumin/99mTc-macroaggregates of albumin, in the tumor lesion. Hybrid images (optical + SPECT) and 3D navigation images with gamma probe are obtained using freehandSPECT.In the operating room, 4–5 images are obtained with freehandSPECT, (I) on skin for tumor location, (II) after exposure of surgical bed for resection guide, (III) of the surgical bed after exeresis, (IV and V) the anterior–posterior and lateral surface of the surgical specimen. The three criteria to decide to extend the margins are: (a) residual activity (cps) at the edges of the surgical bed resection; (b) visual analysis of the uptake in the specimen; (c) a minimum distance of 10 mm from the edges of the specimen to the center of greatest uptake, plus the radius of the lesion.We study the concordance of: the depth measurement between ultrasound and freehandSPECT; the surgical margins between freehandSPECT vs. mammography of the specimen (RxM), considering anatomical pathology (AP) as the gold standard technique as reference; surgical time used with freehandSPECT and RxM. ResultsIntraoperative localization was performed in all cases.False negative (FN: no detection margin affected) with freehandSPECT: 9 margins; with RxM: 8. True positive (TP: detection margin affected) with freehandSPECT: 5 margins, with RxM: 6. True negative (TN: consider free margin when healthy) with freehandSPECT: 213 margins; with RxM: 196. Negative predictive value (NPV: probability of negative margin on unaffected part) with freehandSPECT: 95.9%, with RxM: 96.07%. Specificity with freehandSPECT: 96.8%, with RxM: 97%.The concordance of surgical bed margins between freehandSPECT and RxM: 94.5%. Between freehandSPECT and AP: 93.1%. Between RxM and PA: 93.5%, being all statistically significant (p-value <0.000), so we can affirm that both techniques are related or dependent on the reference technique, the PA. Degree of correlation between SPECT-portable and low PA (Kappa index: 0.34, 95% CI [0.22–0.47], and between RxM and moderate PA (Kappa index: 0.42, 95% CI [0.29–0.56], p-value <0.001. Comparison of the successes and failures of both techniques (SPECT-portable and RxM) and PA: Distribution χ2: 0.023 with degree of freedom 1, with value <0.05, so we can affirm that both techniques are similar, since there are no significant statistical differences.Median total OR time: 60.25 min (30–145). Mean freehandSPECT OR time: 5 scans = 10 min. ConclusionsThere are no statistically significant differences in the probability to rule out affective margins that require a second surgery between both techniques (SPECT-portable and RxM) so, the technique performed with SPECT-Portable is a useful and effective procedure, which requires specific training with an optimized and multidisciplinary protocol. The time spent with SPECT-portable is feasible for daily practice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.