Abstract

AimThe aim of this study is the implementation in a Hospital Radiopharmacy Unit of a risk analysis methodology in order to proactively identify possible failure modes and prioritize corrective measures. Materials and methodsBy means of the failure modes and effects analysis (FMEA), the possible failure modes of each of the stages of the processes of prescription, preparation, and administration of radiopharmaceuticals for diagnostic and therapy were identified. From the variables of severity, probability and detectability, the risk was quantified using the Risk Priority Number (RPN) for each failure mode, sub-process, and type of radiopharmaceutical. Improvement measures were established and the reduction in the RPN value was calculated. ResultsA total of 96 failure modes were identified (58 for diagnostic radiopharmaceuticals and 38 for therapy). Biunivocal identification of the patient with the radiopharmaceutical is the failure mode with the highest RPN (60) and the radiolabeling cell sub-process the one that has the highest risk (RPN 286). As a result of the improvement measures, the overall RPN was reduced by 22% for diagnostic radiopharmaceuticals and 20% for therapy. This reduction would be 46% and 31% respectively if radiopharmacy software and a barcode technology in the administration were implemented. ConclusionsThe application of the FMEA methodology as a risk analysis tool allows to identify the critical points of the processes related to radiopharmaceuticals and prioritize measures to reduce the risk.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call