Abstract

This paper presents the implementation of the data acquisition system of the Resistive Plate Chamber (RPC) subdetector in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) in CERN. The described readout system connects with the RPC detector, the RPC link system, the RPC trigger system and the CMS data acquisition system and creates one of multiple metrological systems in CMS experiment. The readout system receives the data provided by the multiple channels of the link system, filters out the non-triggered data, encapsulates the data into the standard CMS common data format events and sends them to the global data acquisition system. The main problem in the readout system design was to provide a sufficiently large throughput to reliably transfer the data. The implemented system is the scalable solution based on advanced Field Programmable Gate Arrays (FPGA) technology.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call