Summary form only given, as follows. This paper reports on the initial implementation of a monolithic plasma opening switch (MPOS) on the Decade Quad (DQ). The recent installation of a water convolute combining the power flow from the four DQ modules to drive a plasma radiation source (PRS) enables a MPOS configuration for driving a bremsstrahlung radiation source (BRS). The conduction phase requirement for the DQ MPOS is roughly 8 MA for 300 ns. Numerical simulations and experimental results on ACE 4 suggest that the dominate parameter controlling the POS operation is the conduction phase I*T product. The ACE 4 POS design, characterized at an I*T product of 2.4 MA-/spl mu/s, was installed and tested on the water-convoluted DQ configuration. The work reported here will contrast the observed performance of the unoptimized ACE 4 POS on DQ with that expected based on scaling from ACE 4. Optimization of the DQ monolithic POS is planned for a later phase of the present work.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.