Abstract

To utilize cast-in-place self-consolidating concrete (SCC) for caissons on a rural bridge replacement, specifications were first written as guidelines. A mix design was developed and tested in a reusable trial caisson that would simulate field casting conditions. A fresh sampling technique was devised to investigate the distribution of SCC within the trial caisson. Petrographic analysis of hardened samples was done to quantify the amounts of aggregates present at twenty different locations within the trial caisson. The SCC mix design was then successfully used to cast caissons of one of the two bridge abutments, with no major defects detected by cross-hole sonic logging (CSL). Hardened property tests revealed SCC compressive strengths and modulus of elasticity values that were similar to a traditional caisson concrete used on the project, while the total measured shrinkage and the splitting tensile strengths of the field SCC were seen to be lower than those of the traditional caisson concrete.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.