Abstract

Due to the presence of a high-frequency LC tank circuit, dynamics of a resonant converter are unpredictable, often with large surge of tank energy during transients. Employing state-plane analysis technique, a novel “optimal trajectory control” utilizing the desired solution trajectory as the control law has been previously proposed for the series resonant converters. The method predicts the fastest response possible with minimum energy surge in the resonant tank. The principle of the control and its experimental implementation are described. The dynamics of the converter are shown to be close to time-optimal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.