Abstract

Purpose – One of the key components of the micro-sensors is MEMS micro-hotplate. The purpose of this paper is to introduce a platinum micro-hotplate with the proper geometry using the analytical model based on the heat transfer analysis to improve both heating efficiency and time constant. Design/methodology/approach – This analytical model exhibits that suitable design for the micro-hotplate can be obtained by the appropriate selection of square heater (LH) and tether width (WTe). Based on this model and requirements of routine sample loading, the size of LH and WTe are chosen 200 and 15 μm, respectively. In addition, a simple micro-fabrication process is adopted to form the suspended micro-heater using bulk micromachining technology. Findings – The experimental results show that the heating efficiency and heating and cooling time constants are 21.27 K/mW and 2.5 ms and 2.1 ms, respectively, for the temperature variation from 300 to 400 K in the fabricated micro-hotplates which are in closed agreement with the results obtained from the analytical model with errors within 5 per cent. Originality/value – Our design based on the analytical model achieves a combination of fast time constant and high heating efficiency that are comparable or superior to the previously published platinum micro-hotplate.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call